Bedienungsanleitung Cyber Power OP1500AVR T4

Cyber Power OP1500AVR T4

Sprache(n):
Englisch


Dateigröße:
159,69KB

Downloadzeit:
DSL 16k: 1s

Downloads bisher: 1

Hersteller:
Cyber Power 

  • Backup Batterie Cyber Power OP1500AVR T4


  • Vorschau Cyber Power OP1500AVR T4 Handbuch:
    BATTERY REPLACEMENT AND STORAGE Contact your dealer or call the number in this manual for information on battery replacement. Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of personnel knowledgeable of batteries and their precautions. Keep unauthorized personnel away from batteries. CAUTION! Use only the specified type of battery. See your dealer for replacement batteries. CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as they may explode. Follow all local ordinances regarding proper disposal of batteries. CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic. CAUTION! A battery can present a high risk of short circuit current and electric shock. Take the following precautions before replacing the battery: 1. Remove all watches, rings or other metal objects. 2. Only use tools with insulated handles. 3. DO NOT lay tools or other metal parts on top of battery or any battery terminals. 4. Wear rubber gloves and boots. 5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance. TECHNICAL SPECIFICATIONS Model OP1500AVR-T4 Capacity (VA) 1500VA Capacity (Watts) 900W Input Input Voltage Range 85Vac – 150Vac Frequency Range 50/60 Hz +/- 3Hz Output On Battery Output Voltage Simulated Sine Wave at 120Vac +/- 7% On Battery Output Frequency 47-53Hz for 50Hz nominal, 57-63Hz for 60Hz nominal Transfer Time (Typical) 4ms Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting Surge Protection and Filtering Lightning / Surge Protection Yes Internet Ready (DSL / Phone / FAX / Modem Protection) RJ11/RJ45 (One In/One Out) Physical Total # of UPS Receptacles (6) NEMA 5-15R Dimensions (cm) 42.0*18.0*23.5 Weight (kg) 25.4 Battery Sealed Maintenance Free Lead Acid Battery 12V / 17AH x 2 Hot Swappable Battery Yes Typical Recharge Time 8 Hours Warning Diagnostics Indicators Power On, Using Battery, AVR, Wiring Fault, Load Level, Battery Level Audible Alarms On Battery, Low Battery, Overload Environmental Operating Temperature +32°F to 95°F ( 0°C to 35°C ) Operating Relative Humidity 0% to 95% Non Condensing Communication PowerPanel Plus TM Software Windows 95/98/ME/NT/2000/XP, Server 2003, Mac OSX, Linux Management Self-Test Manual Self-Test Auto-Charger/ Auto-Restart/USB Yes SNMP/ HTT .....
    Klicken Sie jetzt für den Download