Bedienungsanleitung Jablotron JK 84

Jablotron JK 84

Sprache(n):
Englisch


Dateigröße:
118,82KB

Downloadzeit:
DSL 16k: 1s

Downloads bisher: 1

Hersteller:
Jablotron 

  • Alarmanlagen Kit Jablotron JK 84


  • Vorschau Jablotron JK 84 Handbuch:
    The JK-84 “Oasis” wireless alarm kit 2 / 2 MKE59901 tab 4. Enrolling more wireless devices The system can be extended with more wireless devices (a maximum of 50 can be enrolled). To enroll another device, the CP should be in service mode, if it is not enter ∗ 0 8080 (while the system is unset). 1. On the keypad, key in 1 to enter enrollment mode. 2. The next vacant address is displayed (scroll to other addresses using the arrow keys if desired). 3. Connect up the device’s battery to enroll the device to the CP. Successful enrollment is confirmed by the A indicator lighting. The next vacant address is then displayed. o The RC-86 key-fob can also be enrolled by pressing and holding a pair of its buttons + (or + ). 4. Exit enrollment mode by pressing the # key. • To enroll the CP to UC-82 or AC-82 modules, enter 299 while the CP is in service mode with the receiving module in enrollment mode. 5. Testing device functionality 1. The CP should be in Service mode, if not enter ∗ 0 8080 2. First trigger the device under test (e.g. a detector). The keypad (with its flip cover open) then indicates triggering of the device if the device is functioning correctly and is enrolled. • Motion detectors are best tested within 15 minutes of closing their covers as after that they only react to frequent movements once every 5 minutes (to restart a device’s test mode, open and close the detector housing again). 6. Checking a device’s radio signals 1. The CP must have its antenna connected and should be in Service mode, if not enter ∗ 0 8080 2. Enter 298, the lowest address with enrolled device will be displayed. 3. Trigger the device linked to this address – the keypad (with its flip cover open) then shows the device’s signal strength in the range ¼ to 4/4 (it should be at least 2/4, if not, relocate the device) o Motion detectors are best tested within 15 minutes of closing their covers as after that they only react to frequent movements once every 5 minutes (to restart a device’s test mode, open and close the detector housing again). o To test the JA-80F keypad signal, trigger the connected magnetic door sensor or activate the keypad’s tamper sensor. o To test the JA-80L siren signal, press the siren’s button. 4. To select the next enrolled device address use the arrow keys. 5. To exit signal measurement mode, press the # key. 7. Programming the system 1. The CP should be in Service mode, if not enter ∗ 0 8080 2. Enter the appropriate programming sequences to select the desired functions (a complete list of them is in the CP and communicator manuals). Function Sequence Note New service co .....
    Klicken Sie jetzt für den Download