Bedienungsanleitung Rane RPM 88

Rane RPM 88

Sprache(n):
Englisch


Dateigröße:
223,96KB

Downloadzeit:
DSL 16k: 1s

Downloads bisher: 1

Hersteller:
Rane 

  • Audio System Rane RPM 88


  • Vorschau Rane RPM 88 Handbuch:
    Manual- Front Panel Description INPUT 1 2 3 4 5 6 7 8 OUTPUT 1 2 3 4 5 6 7 8 PRESET RPM 88 A B A B Peak dBFS -4 -12 -48 -4 -12 -48 -4 -12 -48 -4 -12 -48 AES3 AES3 LOCK PROGRAMMABLE MULTIPROCESSOR VIP/VOP RW 485 ETHERNET STATUS POWER 1 2 3 4 5 6 7 8 1 Signal/Overload LED meters indicate the presence of significant audio signal or overload. These 3-segment meters indicate the avail- able headroom once the analog signal has been converted to digital: -4 dBFS (red, near clipping), -12 dBFS (yellow, high normal level), and -48 dBFS (green, low level). The analog signal level depends on the in- put and output settings and is displayed in Drag Net’s Meter window. 2 AES3 LOCK LED lights solidly when a valid AES3 digital signal is detected on the AES3 input jack. There does not need to be an audio signal present at the input, only the “carrier” signal. 3 PRESET LED displays the number of the most recently recalled Preset, numbered 0 through 24. 4 VIP/VOP LED flashes when a change is detected on the Versatile Input Port (VIP) or Versatile Output Port (VOP). These ports are used for direct electrical connections to potentiometers, switches or other logic ports. The Versatile Input Port accepts up to eight contact closures or voltages; the Versatile Output Port drives eight loads (logic on/off). 5 RW 485 LED flashes when a change in setting is detected on the RW 485 Remote Interface Port. RW 485 is a serial communications protocol primarily used for Rane’s Smart Remotes. 6 ETHERNET LED flashes when an Ethernet data packet for this device is received. 7 STATUS LED reflects the overall status of the unit: Red - initializing (briefly) or possible internal error. Yellow - working, but not currently processing audio. Green - processing audio. 8 POWER LED lights solidly when the unit is powered on. Manual- Rear Panel Description INPUTS + – + – + – + – 4 3 2 1 OUTPUTS + – + – + – + – 8 7 6 5 + – + – + – + – 4 3 2 1 + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – 8 7 6 5 AES3 OUT AES3 IN +12 VERSATILE OUTPUT PORT OPEN COLLECTOR 1 2 3 4 5 7 6 8 +40 VDC / 100 mA MAX 100 mA MAX GND +12 1 2 3 4 5 7 6 8 GND +5v / 100 mA 0-5V REF 1 2 3 4 5 7 6 8 GND REF 1 2 3 4 5 7 6 8 GND VERSATILE INPUT PORT 100-240V 55 WATTS 50/60 Hz FOR CONTINUED GROUNDING PROTECTION DO NOT REMOVE SCREW RPM 88 ACN 001 345 482 MADE IN U.S.A. RANE CORP. DEFAULT LAN 10Base-T LINK REMOTE INTERFACE PORT A B +V -V A B +V -V (RW 485) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device .....
    Klicken Sie jetzt für den Download