Service Faults Displayed on LED Keypads Light Fault Condition 1 AC Fail 2 Telephone Line Fault 3 2-Wire Smoke Alarm 4 Box Tamper & Auxiliary Input: Press . to view type, lights 1 - 5 indicate: Light 1 = Box Tamper Light 2 = Auxiliary Tamper Light 3 = Auxiliary PA Light 4 = Auxiliary Tamper (UK Bell Module) Light 5 = Bell Tamper (UK Bell Module) 5 Date or Time Lost 6 Zone Tamper/Trouble Press 3 to view zone number 7 Keypad Tamper/Removed Press 1 to view keypad number 8 Equipment Faults Press 4 to view fault type: Light 1 = Output 1 Fault Light 2 = Output 2 Fault Light 3 = Siren/Bell Fault Light 4 = 2-Wire Smoke Sensor Fault Light 5 = Auxiliary Fuse Failed Light 6 = Battery Fault Light 7 = Service Timer/Zone Soak Test Failed Light 8 = Communication Fault © Texecom Ltd. 2000 - 2003 INS197-2 Bedienungsanleitung .....